Welcome to Iightstrade.com!

Provide LED lighting Full Safety Testing, EMI testing, Energy Efficiency testing and Certificate

MOQ :1 set

Lead Time :15 Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : Other

Departure Port : Shenzhen

Product details

Supply Ability

  • Supply Ability:1000 piecesWarranty(Year):1 Year

Product Specifications

  • Brand name:Testing

Product Description

If you need do the CE, ROHS, FCC certification for your products, we can provide full tesing and certificate service for you in this field. We are the one of most professional third party testing laboratory in China, and can provide you all the CE,LVD,EMC, R&TTE, MD, ROHS, FCC, CB, SAA, C-TICK, PSE, KC, Saudi Arabic SASO,Iraq CoC, SGS/ITS/BV Pre-shipment inspection service;

 

Our testing and certification scope:

 

Information technology equipment

-Safety-Part 1: General requirement:

GB 4943.1; IEC 60950-1; EN 60950-1; AS/NZS 60950.1; UL60950-1;

 

-Radio disturbance characteristics-Limits of measurement:

GB 9254, EN 55022, CISPR 22, AS/NZS CISPR 22, FCC PART 15

 

-Immunity characteristics-Limits and methods of measurement ofmeasurement:

GB/T 17618-1998, EN 55024:2010, CISPR 24:2010

 

-Electromagnetic compatibility-Limits-Limits for harmonic currentemissions (equipment input current<16 A per phase):

GB17625.1, EN61000-3-2, IEC61000-3-2, AS/NZS 61000.3.2

 

-Electromagnetic compatibility-Testing and measurement techniques-Electrostaticdischarge immunity test: 

GB/T17626.2, EN 61000-4-2, IEC 61000-4-2

 

Audio,video and similar electronic apparatus

-Safetyrequirements:

GB 8898; IEC 60065;EN 60065;AS/NZS 60065; UL 60065

 

-Soundand television broadcast receivers and associated equipment - Radio disturbancecharacteristics - Limits and methods of measurement:

GB 13837; CISPR 13; EN 55013

 

-Soundand television broadcast receivers and associated equipment - Immunitycharacteristics - Limits and methods of measurement:

GB/T9383; EN55020; CISPR 20

 

-Electromagnetic compatibility-Limits-Limits for harmonic currentemissions (equipment input current≤16 A per phase):

GB17625.1, EN61000-3-2, IEC61000-3-2, AS/NZS 61000.3.2

 

-Electromagnetic compatibility-Testing and measurement techniques-Electrostaticdischarge immunity test: 

GB/T17626.2, EN 61000-4-2, IEC 61000-4-2

 

Householdand similar electrical appliances: -general requirements

IEC 60335-1:2010; EN 60335-1:2012; AS/NZS 60335.1: 2011+A1: 2012

-Safety Part 2-3: IEC/EN60335-2-2

-Safety Part 2-3: IEC/EN60335-2-3

-Safety Part 2-3: IEC/EN60335-2-4

-Safety Part 2-3: IEC/EN60335-2-5

-Safety Part 2-3: IEC/EN60335-2-6

-Safety Part 2-3: IEC/EN60335-2-7

-Safety Part 2-3: IEC/EN60335-2-8

-Safety Part 2-3: IEC/EN60335-2-9

-Safety Part 2-3: IEC/EN60335-2-10

-Safety Part 2-3: IEC/EN60335-2-15

-Safety Part 2-3: IEC/EN60335-2-XX

 

-Electromagneticcompatibility-Requirements for household appliances, electric tools and similarapparatus-Part 1: Emission:

GB4343.1; CISPR14-1;AS/NZSCISPR14.1; EN55014-1

 

-Electromagneticcompatibility Requirements for household appliances, Part 2: Immunity-Product:

GB 4343.2, EN 55014-2, CISPR14-2

 

-Electromagnetic compatibility-Limits-Limits for harmonic currentemissions (equipment input current≤16 A per phase):

GB17625.1, EN61000-3-2, IEC61000-3-2, AS/NZS 61000.3.2

 

-Electromagnetic compatibility-Testing and measurement techniques-Electrostaticdischarge immunity test: 

GB/T17626.2, EN 61000-4-2, IEC 61000-4-2

 

Householdand similar electrical appliances - Electromagnetic fields - Methods forevaluation and measurement

EN 62233 ;IEC 62233

 

Electricalsafety of machinery - Electrical equipment of machines - Part 1: Generalrequirements

GB 5226.1; IEC 60204-1; EN60204-1

--------------------------------------------------------------------------------------------------------------------

Luminaires- Part 1: General requirements and tests

GB 7000.1;IEC 60598-1;EN60598-1;AS/NZS 60598.1

 

Limitsand methods of measurements of radio disturbance characteristics of electricallighting and similar equipment

GB 17743;EN 55015; CISPR 15;AS/NZS CISPR 15

 

Equipmentfor general lighting purposes-EMC immunity requirements

GB 18595;EN 61547;IEC61547

 

Assessmentof lighting equipment related to human exposure to electromagnetic fields

IEC 62493;EN 62493

 

Luminaires- Part 2: Particular Requirements

SectionOne - Fixed General Purpose Luminaires                          

GB 7000.201;IEC60598-2-1;EN60598-2-1:1989;AS/NZS60598.2.1

 

Luminaires- Part 2: Particular requirements -- Section 2: Recessed luminaires

GB 7000.202;IEC60598-2-2;EN60598-2-2;AS/NZS60598.2.2

 

Luminaires- Part 2-3: Particular requirements --Luminaires for road and street lighting

GB 7000.5;IEC 60598-2-3;EN60598-2-3;AS/NZS60598.2.3

 

Luminaires-Part 2: Particular requirements Section 4: Portable general purposeluminaires

GB 7000.204;IEC 60598-2-4;EN60598-2-4;AS/NZS60598.2.4

 

Luminaires- Part 2-5: Particular requirements -Floodlights

GB 7000.7;IEC 60598-2-5;EN60598-2-5;AS/NZS60598.2.5

 

Luminaires- Part 2 Particular requirements - Section 7: Portable luminaires for gardenuse

GB 7000.207;IEC 60598-2-7;EN 60598-2-7; AS/NZS 60598.2.7

 

Luminaires-- Part 2-8 Particular requirements -Handlamps

GB 7000.208;IEC 60598-2-8,EN 60598-2-8;AS/NZS 60598.2.8

 

Luminaires-Part 2-10:Particular requirements -Portable luminaires for children

GB 7000.4;IEC 60598-2-10;EN60598-2-10;AS/NZS60598.2.10

 

Luminaires-Part 2-11 aquarium Luminaires

GB 7000.211;IEC 60598-2-11;EN60598-2-11

 

Luminaires-Part 2-12:Particular requirements -Mains socket-outlet mounted nightlights

GB 7000.212;IEC 60598-2-12;EN60598-2-12

 

Luminaires-- Part 2-17: Particular requirements -- Section seventeen: Luminaires forstage lighting, television film and photographic studios (outdoor and indoor)

GB 7000.217;IEC 60598-2-17,EN60598-2-17;AS/NZS 60598.2.17

 

LuminairesPart 2:Particular requirements Section 18: Luminaires for swimming pools andsimilar applications

GB 7000.218;IEC 60598-2-18;EN60598-2-18,AS/NZS60598.2.18

 

Luminaires-- Part 2-20: Particular requirements -Lighting chains

GB 7000.9;IEC/EN60598-2-20; AS/NZS60598.2.20

 

Luminaires -- Part 2-22: Particular requirements --Luminaires for emergency lighting

GB7000.2;IEC60598-2-22;EN60598-2-22;AS/NZS60598.2.22

 

Self-ballastedlamps for general lighting services - Safety requirements

GB 16844;IEC60968; EN60968; AS/NZS60968

Self-ballastedLED-lamps for general lighting services by voltage > 50 V - Safety

Specifications

GB 24906; IEC62560, EN 62560

DCor AC supplied electronic control gear for LED modules-Performance requirements

GB/T 24825;IEC 62384;EN62384

 

LED modules for generallighting-safety specifications

GB24819;IEC62031;EN62031

Lampcontrol gear -- Part 1: General and safety requirements

GB 19510.1;IEC 61347-1;EN61347-1;

AS/NZS61347.1

 

Lampcontrol gear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronicstep-down convertors for filament lamps

GB 19510.3;IEC61347-2-2;EN61347-2-2;AS/NZS61347.2.2

 

Lampcontrol gear -Part 2-3:Particular requirements for a.c. supplied electronicballasts for fluorescent lamps

GB 19510.4;IEC61347-2-3;EN61347-2-3;AS/NZS61347.2.3

Lampcontrol gear -Part 2-8:Particular requirements for ballasts for fluorescentlamps

GB 19510.9;IEC61347-2-8;EN61347-2-8;AS/NZS61347.2.8

 

Lampcontrol gear -Part 2-12: Particular requirements for d.c. or a.c. suppliedelectronic ballasts for discharge lamps (excluding fluorescent lamps)              

GB 19510.10;IEC 61347-2-12;EN61347-2-12

 

Lampcontrol gear - Part 2-13: Particular requirements for d.c. or a.c. suppliedelectronic control gear for LED modules

GB19510.14;IEC 61347-2-13;EN61347-2-13;AS/NZS 61347.2.13


Please Contact:

Edison Xia  Sales Executive

Shenzhen LCS Compliance Testing Laboratory Ltd.

ADD: 1F., Xingyuan Industrial Park, Tongda Road, Bao'an Blvd.,

Bao'an District,Shenzhen, Guangdong, China

Ph: + (86) 1382885 4320

Tel: + (86) 75582591330 (Ext.8057)

Fax:+ (86) 75582591332

E-mail:edison.xia@lcs-cert.com

QQ: 863253430 Skype: Lucky.dog12

You May Like